Introduction and operation of suction and purification vehicle

Basic operation process of suction and purification vehicle:

1. Park the vehicle in the construction position (compare the horizontal area, the slope is too large to affect the suction and blanking effect);

2. Place warning belts and construction warning marks;

3. Connect to the power supply and water source; (Start the generator if there is no power supply)

4. Open the stirring motor switch of the pharmaceutical cabinet and mix the potion; The concentration of the potion measured by the finger is sticky and filamentous;

5. Connect the suction pipe and drain pipe and open the manhole cover to dilute the septic tank;

6. Start sucking feces;

7, open the dosing pump switch;

8, open the flocculating machine switch (see whether the feces water separation);

9. Put fecal water into the warehouse;

10, see how much excrement slag outflow of flocculating machine bin, only open the dehydrator switch slag removal;


Suction and purification car points for attention:

1. If the suction is not enough or can not suck into the slag, there may be twigs, toothbrushes, and debris to jam the pipe, to check and clean in time;

2. Keep the vacuum state of the tube and the vacuum pump in the box. If there is air in, the suction may be insufficient or slow.

3. Fill the vacuum pump tank with water (ensure that the water in the tank is not lower than the water level mark during use)

4. Start the generator, start the fuel valve, the frequency is between 50-52HZ, the voltage indicator is 400, then fix the throttle, close the switch on the side.

5. Start the barrel, turn on the vacuum pump switch, and check whether it is positive rotation (if it is reversed, stop the machine first, open the electric box door, and push the commutator switch in the upper left corner to the other side. If you use external power supply, you must ensure that the live line and the neutral line can not be reversed, if it is reversed, it will burn the transformer, start the switch will burn the switch of the electrical adapter, and the fuse.

6. Open the gate valve to drain water (grease the gate valve plate regularly, once every two days)

7. The barrel should be cleaned up in time. In the case of a large amount of garbage in the septic tank, the garbage should be put once per car. (In other cases, not more than five cars, it is necessary to put garbage, if the garbage discharge is not timely, it is easy to cause damage to the bearing and motor in the barrel, as well as the switch in the electric box.)

 

 

Late notes and maintenance of vehicles:
1. If the vacuum pump does not automatically stop working after the sewage tank is full, stop the machine first to check the induction rod of the sewage tank. There are two stainless steel induction rods in the sewage tank on the roof, which cause the induction is not sensitive.

The second situation is that the vacuum does not work may be the induction rod electrode seat has water, resulting in induction rod failure, to dry can be used normally.

2, the engine oil in the use of 100 hours or so to change, to regularly check the generator water tank, in the process of use can not open the water tank, in case of scald, must be completely cold water tank to open.

3. When cleaning the equipment, we must pay attention to not letting water into the motor to ensure that the motor can be used normally.

4. Check whether the screws in the electric box are loose regularly to prevent damage to the equipment.

5. Regularly check whether the screws on the equipment are loose.

6, regular cleaning stainless steel vacuum separation and stainless steel storage box.

7. There is an oil hole in the upper part of the back of the barrel motor, and oil is added once every 3 months. The type of oil is 00# semi-fluid grease.